The DTXA Adapter (IBM ARTIC960RxD Quad Digital Trunk PCI Adapter) is supported on the following RS/6000 Models:


The DTXA Adapter (IBM ARTIC960RxD Quad Digital Trunk PCI Adapter) is supported on the following pSeries and System p5 Servers:


The DTTA Adapter (IBM Quad Digital Trunk Telephony PCI Adapter and IBM Quad Digital Trunk Telephony PCI Blind Swap Adapter PCI Adapter) are supported on the following pSeries, System p5, and p6 Servers:


The DTEA Adapter (IBM Digital Telephone Ethernet Adapter) is supported on the following pSeries and System p5 Servers:


Note1: The Quad Digital Trunk Telephony PCI Adapter (DTXA) and the Quad Digital Trunk Telephony PCI Blind Swap Adapter cannot reside in the same system with the IBM ARTIC960RxD Quad Digital Trunk PCI Adapter (DTTA).


Note2: The Quad Digital Trunk Telephony PCI Adapter (DTXA) and the Quad Digital Trunk Telephony PCI Blind Swap Adapter are supported only in machines running in a full system partition.


Adapter placement Quick Reference Table for Version 4 Release 2




This document gives information on recommended adapter configurations. It is the best information we have to date, and we will update it when later information is available. If you still have problems after following this guidance, then please call IBM Software Support.


Note: The DTQA adapter (Digital Trunk Quad Adapter) is not supported by Blueworx Voice Response V4.2 or later.


Note: The DTXA adapter (Quad Digital Trunk Telephony PCI Adapter) is not supported by Blueworx Voice Response V6.1 or later.


Blueworx Voice Response supports Brooktrout TR114-P16S and TR1034 Fax adapters in certain systems as described in the system specific guidelines.
Note: The Brooktrout TR114-P16S Fax adapter requires a 5V PCI slot. See the guidance for your machine type for more details.
To attach the Brooktrout SCBus connector to the H.100 DTXA connector it is necessary to use a combination of the following features:

  • Feature 2877: H.100, 4-Drop Cable
  • Feature 4354: H.100, 8-Drop Cable


To install the Brooktrout adapter TR114-P16S and have it recognized by AIX in systems with Hot Plug PCI slots (eg 7026-6H1) it is necessary to install a special resistor pack in place of the 20-pin PEB resistor pack which is removed. The Brooktrout FAX adapter TR114-P16S, special resistor pack, and instructions on when and how to install it are available from Brooktrout as Part Number 900-116-09.

Note: Information on the placement of other adapters can be obtained from the PCI Adapter Placement Reference SA38-0538.



General Adapter guidance

  1. DTXAs must be close enough to allow the H.100/SCBus cable connection.
  2. All installed DTXAs must be connected together with the H.100/SCBus cable which also connects to a Brooktrout adapter.
  3. DTTAs/DTEAs must be close enough to allow the H.100 cable connection.
  4. All installed DTTAs must be connected together with the H.100 cable.
  5. All installed DTEAs must be connected together with the H.100 cable.
  6. The Brooktrout Fax adapter TR114-P16S is only supported in combination with the DTXA adapter. (It is not supported in combination with the DTTA or DTEA adapters)
  7. The Brooktrout Fax adapter TR1034 is only supported in combination with the DTTA adapter. (It is not supported in combination with the DTXA adapters)
    Note: It will co-exist with the DTEA adapter but it is not possible to send or receive FAXes using the DTEA adapter.
  8. IBM PCI Token Ring Adapters (14101800) MUST be in logical slot numbers less than the DTXAs.
  9. DTXAs and DTTAs may NOT be installed together.





LPAR guidance

  1. BVR only supports LPAR on the following systems:
    p5 520 Type 9111-520
    p5 520 Type 9131-52A
    p5 550 Type 9113-550
    p5 550 Type 9133-55A
    p5 570 Type 9117-570
    p6 520 Type 8203-E4A
    p6 550 Type 8204-E8A
    p6 570 Type 9117-MMA

    Note: BVR will also run on these systems in non-LPAR mode, both for AIX 5.2, AIX 5.3 and AIX 6.1.
  2. BVR supports LPAR on AIX 5.3 ML02 or higher.
  3. BVR can be installed in either of the following and this install is defined as one instance:
    A single Dynamic Logical Partition as provided by AIX 5.3
    A system running a single image of AIX 5.2 or 5.3, and NOT using LPAR
  4. Although the systems indicated above in general can host many LPAR's, any given system is limited to a maximum of two LPAR's hosting BVR.
  5. One or two additional I/O drawers may be required to attach to the systems in order to provide sufficient slots for BVR hardware adapters and any other adapters used by the system or LPARs.
  6. Where a BVR instance has more than one hardware adapter, the adapters must be linked with an internal H.100 cable, and hence must reside in the same system or I/O drawer, ideally in adjacent slots. The pSeries 7311-D20 I/O Drawer supports 7 adapters therefore to support two LPARs of 4 adapters each requires two pSeries 7311-D20 I/O Drawers to be attached.
  7. The DTXA adapter, SS8 SS7 adapter, and Brooktrout TR1034 FAX adapter are not supported in LPARs.
  8. All Telephony adapters in each LPAR must be installed in the same physical unit (System or 7311-D20 I/O Drawer).
  9. Where a system is hosting two BVR LPARs, the adapters of each BVR LPAR are separate and require separate H.100 cables.
  10. Virtualisation and micro partitioning in LPARs is not supported. This limitation means that each LPAR requires its own Ethernet communications, SCSI disk adapters as well as disks.
  11. It is recommended NOT to run other applications in the same LPAR (or system, if LPAR is not used), as BVR. However, this is not mandatory.
  12. It is recommended that any LPAR hosting BVR should have at least 2 processors, especially where production loads are envisaged.






Specific adapter placement guidance by machine type




RS/6000 7025-F80, pSeries Type 7025-6F0 and pSeries Type 7025-6F1 


Also see General Adapter guidance

  1. A maximum of 4 DTXAs may be installed.
    DTXAs may be installed in slots 9, 10 11 and 12.
    Slot 12 must be left empty if 3 DTXA adapters are installed.
  2. A maximum of 2 Brooktrout Fax adapters TR114-P16S may be installed in slots 6, 7, 11, 1, or 2.
  3. The maximum DTXA + Brooktrout Fax adapters TR114-P16S which can be installed in this system unit is 4.





RS/6000 7025-F50 and 7026-H50


Also see General Adapter guidance

  1. The logical slot ordering should be used to determine which slot to place the IBM PCI Token Ring Adapter (14101800). This order is based on the bus interrupt level assigned to each slot.
    Therefore, the logical slot ordering of the physical slots is as follows:
    Lowest 3 4 5 6 2 1 7 8 9 Highest
    Therefore, the lowest logical slot number is physical slot 3.
  2. Physical slots 1 and 2 are a Primary 64-bit PCI Bus
    Physical slots 3,4 and 5 are a Primary 32-bit PCI Bus
    Physical slots 6, 7, 8 and 9 are a Primary 32-bit PCI Bus
  3. A maximum of 3 DTXAs may be installed.
  4. If only 2 DTXA adapters are installed then we recommend that they are installed in physical slots 1 and 2.
    If 3 DTXA adapters are installed then we recommend that they are installed in physical slots 7, 8 and 9.
    If ISA Adapters are installed in the system, the DTXA adapters MUST NOT installed in physical slots 3, 4, or 5. The DTXA Adapters MUST NOT be installed on the same PCI Bus as any Video Adapter.
  5. A maximum of 2 Brooktrout Fax adapters TR114-P16S may be installed in slots 6, 7 or 8.
  6. The maximum DTXA + Brooktrout Fax adapters TR114-P16S which can be installed in this system unit is 4.






RS/6000 7026-H70


Also see General Adapter guidance

  1. Physical slots 1 and 2 are a primary 64-bit PCI Bus.
    Physical slots 3 and 4 are a primary 32-bit PCI Bus.
    Physical slots 5 and 6 are a primary PCI Bus. (slot 5 64-bit, slot 6 32-bit)
    Physical slots 7 and 8 are a primary PCI Bus. (slot 7 64-bit, slot 8 32-bit)
  2. A maximum of 3 DTXAs may be installed.
  3. A maximum of 2 Brooktrout Fax adapters TR114-P16S may be installed in slots 1 or 2.
  4. The maximum DTXA + Brooktrout Fax adapters TR114-P16S which can be installed in this system unit is 5.





RS/6000 7026-H80 and pSeries 660 Type 7026-6H0


Also see General Adapter guidance

  1. A maximum of 4 DTXAs may be installed.
  2. DTXAs may be installed in consecutive slots in the range 14, 13, 12, 11, 10, 9 or 8.
  3. A maximum of 2 Brooktrout Fax adapters TR114-P16S may be installed in slots 11 and 12.
  4. If internal disks are installed in slots 14 and 13 then Brooktrout Fax adapters TR114-P16S (max 2) should be installed in slots 12 and 11. The remaining slots can have DTXAs installed up to a maximum of 4.
    If internal disks and 2 Brooktrout Fax adapters TR114-P16S are installed then a maximum of 3 DTXAs can be installed.

    Example allowable configurations are as follows:
    (TR114-P16S = Brooktrout Fax Adapter TR114-P16S.



    Slot Number


    8


    9


    10


    11


    12


    13


    14

       
    DTXA


    DTXA


    DTXA


    DTXA

       
    TR114-P16S


    TR114-P16S


    DTXA


    DTXA


    DTXA


    DTXA


    DTXA


    TR114-P16S


    TR114-P16S

      
     
    DTXA


    DTXA


    DTXA


    DTXA


    Disk


    DTXA


    DTXA


    DTXA


    DTXA


    TR114-P16S


    Disk


    DTXA


    DTXA


    DTXA


    TR114-P16S


    TR114-P16S


    Disk



  5. The maximum DTXA + Brooktrout Fax adapters TR114-P16S which can be installed in this system unit is 5.






pSeries 660 Type 7026-6H1 


Also see General Adapter guidance

  1. A maximum of 4 DTXAs OR 4 DTEAs may be installed.
    DTXAs and DTEAs may NOT be installed together.
  2. DTXAs OR DTEAs may be installed in consecutive slots in the range 14, 13, 12, 11, 10, 9 or 8.
  3. A maximum of 2 Brooktrout Fax adapters TR114-P16S may be installed in slots 11 and 12.
  4. If internal disks are installed in slots 14 and 13 then Brooktrout Fax adapters TR114-P16S (max 2) should be installed in slots 12 and 11. The remaining slots can have DTXAs or DTTAs installed up to a maximum of 4.
    If internal disks and 2 Brooktrout Fax adapters TR114-P16S are installed then a maximum of 3 DTXAs or 3 DTTAs can be installed.

    Example allowable configurations are as follows:
    (TR114-P16S = Brooktrout Fax Adapter)



    Slot Number


    8


    9


    10


    11


    12


    13


    14

       
    DTXA


    DTXA


    DTXA


    DTXA

       
    TR114-P16S


    TR114-P16S


    DTXA


    DTXA


    DTXA


    DTXA


    DTXA


    TR114-P16S


    TR114-P16S

      
     
    DTXA


    DTXA


    DTXA


    DTXA


    Disk


    DTXA


    DTXA


    DTXA


    DTXA


    TR114-P16S


    Disk


    DTXA


    DTXA


    DTXA


    TR114-P16S


    TR114-P16S


    Disk



  5. The maximum DTXA + Brooktrout Fax adapters TR114-P16S which can be installed in this system unit is 5.



RS/6000 7026-B80 and pSeries 640 Type 7026-B80


Also see General Adapter guidance

  1. A maximum of 4 DTXAs may be installed.
  2. DTXA Adapters may only be installed in slots 1, 2, 3 or 4, starting from slot 1.
  3. A maximum of 2 Brooktrout Fax adapters TR114-P16S may be installed in slots 3 or 4.
  4. If only 2 DTXAs are installed, then do not install a high bandwidth adapter (eg. BG Ethernet, SSA) in slot 3.
  5. The maximum DTXA + Brooktrout Fax adapters TR114-P16S which can be installed in this system unit is 4.





RS/6000 7043-150


Also see General Adapter guidance

  1. Physical slots 1 is a secondary 32-bit PCI Bus
    Physical slots 2 and 3 are a primary 32-bit PCI Bus
    Physical slots 4 and 5 are a secondary 32-bit PCI Bus
  2. A maximum of 2 DTXAs may be installed.
  3. DTXA Adapters may only be installed in slots 2, 3 or 4.
  4. A maximum of 2 Brooktrout Fax adapters TR114-P16S may be installed in slots 3 or 4.
  5. The maximum DTXA + Brooktrout Fax adapters TR114-P16S which can be installed in this system unit is 3.
  6. We recommended that high-speed comms adapters are installed in slots 2 or 3.






RS/6000 7044-170


Also see General Adapter guidance

  1. A maximum of 2 DTXAs may be installed.
  2. DTXA Adapters may only be installed in slots 1, 2, or 3.
  3. A maximum of 3 Brooktrout Fax adapters TR114-P16S may be installed in slots 3, 4 or 5.
  4. The maximum DTXA + Brooktrout Fax adapters TR114-P16S which can be installed in this system unit is 4.





RS/6000 7043-260


Also see General Adapter guidance

  1. Physical slots 1 and 2 are a primary 64-bit PCI Bus
    Physical slots 3,4 and 5 are a primary 32-bit PCI Bus
  2. A maximum of 2 DTXAs may be installed.
  3. The Brooktrout Fax adapters are not supported in this system.
  4. We also recommended that high-speed comms adapters are installed in slots 1 or 2.






RS/6000 7044-270


Also see General Adapter guidance

  1. A maximum of 3 DTXAs may be installed.
  2. DTXA Adapters may only be installed in slots 1, 2, 3 or 4.
  3. If only 2 DTXAs are installed, then do not install a high bandwidth adapter (eg. BG Ethernet, SSA) in the third slot.
  4. A maximum of 3 Brooktrout Fax adapters TR114-P16S may be installed in slots 3, 4 or 5.
  5. The maximum DTXA + Brooktrout Fax adapters TR114-P16S which can be installed in this system unit is 4.






pSeries 610 Type 7028-6C1 and pSeries 610 Type 7028-6E1 


Also see General Adapter guidance

  1. A maximum of 3 DTXAs may be installed.
  2. A maximum of 3 Brooktrout Fax adapters TR114-P16S may be installed in slots 1, 2 or 3.
  3. The maximum DTXA + Brooktrout Fax adapters TR114-P16S which can be installed in this system unit is 5.






pSeries 630 Type 7028-6C4 and pSeries 630 Type 7028-6E4 


Also see General Adapter guidance

  1. A maximum of 4 DTXAs or 4 DTEAs or 4 DTTAs may be installed.
    DTXAs and DTTAs may NOT be installed together.
    Note:

    The 8-drop H.100 cable (FC 4353) should be used for installations with three or more DTXA adapters installed. This is because of the extra wide gap between PCI slots 2 and 3 which the 4-drop cable is not capable of spanning.
    Be sure to use each end of the 8-drop cable and any other drops in-between that are required, the remaining drops can be left unconnected. If only two DTXA adapters are installed, the 4-drop cable will work as long as they are installed in slots 1 & 2 or slots 3 & 4.
  2. A maximum of 4 DTXAs, 4 DTTAs or 4 DTEAs may be installed in an attached pSeries 7311-D20 I/O Drawer.
    When DTXAs, DTTAs or DTTAs are installed in this I/O Drawer then they cannot also be installed in the base pSeries.
  3. A maximum of 1 Brooktrout Fax adapter TR1034 is supported in this system unit.
  4. The maximum DTTA + Brooktrout Fax adapters TR1034 which can be installed is in this system unit 5.






pSeries 615 Type 7029-6C3 and pSeries 615 Type 7029-6E3 


Also see General Adapter guidance

  1. A maximum of 3 DTTAs or 3 DTEAs may be installed in slots 4, 5 and 6.
  2. A maximum of 1 Brooktrout Fax adapter TR1034 is supported in this system unit.
  3. The maximum DTTA + Brooktrout Fax adapters TR1034 which can be installed in this system unit is 3.






pSeries 650 Type 7038-6M2 


Also see General Adapter guidance

  1. A maximum of 4 DTTAs may be installed.
  2. A maximum of 3 DTTAs may be installed in an attached pSeries 7311-D10 I/O Drawer.
    or a maximum of 4 DTTAs may be installed in an attached pSeries 7311-D20 I/O Drawer.
    However when DTTA's are installed in an I/O Drawer then they cannot also be installed in the base pSeries 650-6M2.
  3. The Brooktrout Fax adapters are not supported in this system.






pSeries 7311-D10 I/O Drawer available on pSeries 650-6M2 


Also see General Adapter guidance

  1. A maximum of 3 DTTAs may be installed.
  2. When DTTA's are installed in this I/O Drawer then they cannot also be installed in the base pSeries 650-6M2.
  3. The Brooktrout Fax adapters are not supported in this system.






pSeries 7311-D20 I/O Drawer available on pSeries 7038-6M2, 7028-6C4, 9111-520, 9131-52A, 9113-550, 9113-55A and 9117-570 


Also see General Adapter guidance

  1. The D20 can have a total of 7 Adapters installed.
    See specific system guidance for the maximum number of DTXAs, DTTAs and DTEAs per system or LPAR which can be installed.
  2. The Brooktrout Fax adapters are not supported in this I/O Drawer.






p5 520 Type 9111-520 


Also see General Adapter guidance

  1. A maximum of 3 DTTAs or 3 DTEAs or 3 DTXAs may be installed in this system unit.
    DTXAs and DTTAs may NOT be installed together.
  2. In non-LPAR mode, a maximum of 3 DTXAs or 3 DTTAs or 3 DTEAs may be installed in an attached pSeries 7311-D20 I/O Drawer.
    However when Telephony adapters are installed in an I/O Drawer then they cannot also be installed in the base system unit.
  3. In LPAR mode, a maximum of 3 DTTAs or 3 DTEAs per LPAR may be installed in an attached pSeries 7311-D20 I/O Drawer.
  4. A maximum of 1 Brooktrout Fax adapter TR1034 is supported in this system.
  5. The maximum DTTA + Brooktrout Fax adapters TR1034 which can be installed in the system unit is 3.
  6. BVR supports LPAR only on AIX 5.3 ML02 or higher: see LPAR Guidance
  7. This system has a minimum prereq of AIX Version 5.2 ML04 or later.






p5 520 Type 9131-52A 


Also see General Adapter guidance

  1. A maximum of 3 DTTAs or 3 DTEAs or 3 DTXAs may be installed in this system unit.
    DTXAs and DTTAs may NOT be installed together.
  2. In non-LPAR mode, a maximum of 4 DTXAs or 4 DTTAs or 4 DTEAs may be installed in an attached pSeries 7311-D20 I/O Drawer.
    However when Telephony adapters are installed in an I/O Drawer then they cannot also be installed in the base system unit.
  3. In LPAR mode, a maximum of 4 DTTAs or 4 DTEAs per LPAR may be installed in an attached pSeries 7311-D20 I/O Drawer.
  4. A maximum of 1 Brooktrout Fax adapter TR1034 is supported in this system.
  5. The maximum DTTA + Brooktrout Fax adapters TR1034 which can be installed in system unit is 3.
  6. BVR supports LPAR only on AIX 5.3 ML02 or higher: see LPAR Guidance
  7. This system has a minimum prereq of AIX Version 5.2 ML04 or later.






p5 550 Type 9113-550


Also see General Adapter guidance

  1. A maximum of 4 DTTAs or 4 DTEAs or 4 DTXAs per LPAR may be installed.
    DTXAs and DTTAs may NOT be installed together.
  2. In non-LPAR mode, a maximum of 4 DTXAs or 4 DTTAs or 4 DTEAs may be installed in an attached pSeries 7311-D20 I/O Drawer.
    However when Telephony adapters are installed in an I/O Drawer then they cannot also be installed in the base system unit.
  3. In LPAR mode, a maximum of 4 DTTAs or 4 DTEAs per LPAR may be installed in an attached pSeries 7311-D20 I/O Drawer.
  4. The Brooktrout Fax adapters are not supported in this system.
  5. BVR supports LPAR only on AIX 5.3 ML02 or higher: see LPAR Guidance
  6. This system has a minimum prereq of AIX Version 5.2 ML04 or later.





p5 550 Type 9133-55A


Also see General Adapter guidance

  1. A maximum of 3 DTTAs or 3 DTEAs or 3 DTXAs may be installed.
    DTXAs and DTTAs may NOT be installed together.
  2. In non-LPAR mode, a maximum of 4 DTXAs or 4 DTTAs or 4 DTEAs may be installed in an attached pSeries 7311-D20 I/O Drawer.
    However when Telephony adapters are installed in an I/O Drawer then they cannot also be installed in the base system unit.
  3. In LPAR mode, a maximum of 4 DTTAs or 4 DTEAs per LPAR may be installed in an attached pSeries 7311-D20 I/O Drawer.
  4. The Brooktrout Fax adapters are not supported in this system.
  5. BVR supports LPAR only on AIX 5.3 ML02 or higher: see LPAR Guidance
  6. This system has a minimum prereq of AIX Version 5.2 ML04 or later.






p5 570 Type 9117-570 


Also see General Adapter guidance

  1. BVR adapters are not supported directly installed in the base system unit due to Blind-Swap cassette limitations.
  2. In non-LPAR mode, a maximum of 4 DTXAs or 4 DTTAs or 4 DTEAs may be installed in an attached pSeries 7311-D20 I/O Drawer.
  3. In LPAR mode, a maximum of 4 DTTAs or 4 DTEAs per LPAR may be installed in an attached pSeries 7311-D20 I/O Drawer.
  4. The Brooktrout Fax adapters are not supported in this system.
  5. BVR supports LPAR only on AIX 5.3 ML02 or higher: see LPAR Guidance
  6. This system has a minimum prereq of AIX Version 5.2 ML04 or later (AIX 5.3 is not supported).






p6 520 Type 8203-E4A 


Also see General Adapter guidance

  1. A maximum of 2 DTTAs may be installed in system unit PCI slots.
  2. In non-LPAR mode, a maximum of 4 DTTAs may be installed in an attached pSeries 7311-D20 I/O Drawer.
    However when Telephony adapters are installed in an I/O Drawer then they cannot also be installed in the base system unit.
  3. In LPAR mode, a maximum of 4 DTTAs per LPAR may be installed in an attached pSeries 7311-D20 I/O Drawer.
  4. This system has a minimum prereq of AIX Version 5.3 TL 07 or later.







p6 550 Type 8204-E8A


Also see General Adapter guidance

  1. A maximum of 2 DTTAs may be installed in system unit PCI slots.
  2. In non-LPAR mode, a maximum of 4 DTTAs may be installed in an attached pSeries 7311-D20 I/O Drawer.
    However when Telephony adapters are installed in an I/O Drawer then they cannot also be installed in the base system unit.
  3. In LPAR mode, a maximum of 4 DTTAs per LPAR may be installed in an attached pSeries 7311-D20 I/O Drawer.
  4. This system has a minimum prereq of AIX Version 5.3 TL 06 or later.







p6 570 Type 9117-MMA


Also see General Adapter guidance

  1. BVR adapters are not supported directly installed in the base system unit due to Blind-Swap cassette limitations.
  2. In non-LPAR mode, a maximum of 4 DTTAs may be installed in an attached pSeries 7311-D20 I/O Drawer.
  3. In LPAR mode, a maximum of 4 DTTAs per LPAR may be installed in an attached pSeries 7311-D20 I/O Drawer.
  4. This system has a minimum prereq of AIX Version 5.2 TL 10 or later.







Adapter placement Quick Reference Table for Version 4 Release 2



 
Maximum numbers of adapters


Slot placement


Machine Type


DTXA


DTTA


DTEA


B/T FAX
TR114-P16S


B/T FAX
TR1034


MAX Total


Telephony


B/T Fax



7025-F50
7026-H50


3


0


0


3


0


4


7,8,9


6,7,8


7026-B80
(pSeries 640)


4


0


0


2


0


4


1, 2, 3, 4


3,4


7025-F80


4


0


0


2


0


4


12, 11, 10
9, 8, 7


11, 12


7025-6F0
7025-6F1
(pSeries 620)


7026-H70


3


0


0


2


0


5


6, 7, 8, 5


1, 2


7026-H80


4


0


0


2


0


5


14, 13, 12
11, 10, 9, 8


11,12


7026-6H0
(pSeries 660)


7026-6H1
(pSeries 660)


4


0


4


2


0


5


14, 13, 12
11, 10, 9, 8


11,12


7028-6C1
7028-6E1
(pSeries 610)


3


0


0


3


0


5


Any


1, 2, 3


7028-6C4
7028-6E4
(pSeries 630)


4


4


4


0


1


5
Cannot mix
DTXA and DTTA


Any


Any


7029-6C3
7029-6E3
(pSeries 615)


0


3


3


0


1


3


4, 5, 6


Any


7038-6M2
(pSeries 650)


0


4


0


0


0


0


Any


-


7043-260


2


0


0


0


0


2


1, 2


-


7043-150


2


0


0


2


0


3


2, 3, 4


3,4


7044-170


2


0


0


3


0


4


1, 2, 3


3, 4, 5


7044-270


3


0


0


3


0


4


1, 2, 3, 4


3, 4, 5


7311-D10
attached to
pSeries
650-6M2


0


3


0


0


0


3


Any


-


7311-D20
attached to
pSeries
650-6M2,
630-6C4,
9111-520,
9113-55A,
or 9117-570


7


7


7


0


0


7
See specific
system guidance
for the maximum
per system
or LPAR


Any


-


9111-520
9131-52A


3


3


3


0


1


3
Cannot mix
DTXA and DTTA


Any


Any


9113-550


4


4


4


0


1


4
Cannot mix
DTXA and DTTA


Any


Any


9133-55A


3


3


3


0


1


3
Cannot mix
DTXA and DTTA


Any


Any


9117-570
adapters supported
in attached
D20 I/O Drawer
ONLY


0


0


0


0


0


0


-


-


Machine Type


DTXA


DTTA


DTEA


B/T FAX
TR114-P16S


B/T FAX
TR1034


MAX Total


Telephony


B/T Fax

 
Maximum numbers of adapters


Slot placement